Installation Guide:
Residential Applications - Wood Framing
Typical Ceiling Application
Product
 
Average R-Values

Heat Flow Up: R-42*
Heat Flow Down: R-47.5*

* System R-value is for one enclosed air space. Additional R-4.5 added for a still air film for heat flow down and R-1.3 for heat flow up.

Note: This system without the Flexfoil, utilizes 10" of mass insulation and has an R-Value rating of 38.
Instructions
  1. Measure working area where Flexfoil will be applied.
  2. Fasten the Flexfoil to the bottom of the joist facing using 1/2” staples every 4” - 6”.
  3. The white polyethylene side of the Flexfoil should be facing the mass insulation.
  4. Ensure that all seams are securely taped using Flexfoil reflective tape.
  5. Apply 1 x 3 strapping (at 16” centre) to the Flexfoil, running the length of the ceiling.
  6. Fasten the interior finish to the strapping using approved construction methods.